Saltar al contenido principal

After switch on: priming star for few seconds then E05 error

Dear,

Circuit priming message loops at beginning, then straigth away E05 error and asking to restart the machine, I did few times without sucess.

I opened the machine, and I can`t see any leak.

Any recommendation please?

My  coffee machine is Royal gran crema

Contestado! Ver respuesta Yo también tengo este problema

Es esta una buena pregunta?

Puntuación 0
1 comentario

Hi . The problem with E05 is generated of many SAECO coffee machine , I had this problem and I fixed it . See the video below and I am sure it will helps you .

https://youtu.be/0YR-xtacx1U

- de

Agregar un comentario

1 Respuesta

Solución Elegida

Error code 05 means that the flow meter does not give a signal. Now you have to search: is the flowmeter blocked or broken? Or the water cannot pass through, e.g. because the heater or the pump is calcified. In Saeco Royal Pumpe austauschen the flowmeter can be seen in step 6, picture 2. Open the flowmeter and clean it, it's easy.

Fue útil esta respuesta?

Puntuación 1
Agregar un comentario

Añadir tu respuesta

anass estará eternamente agradecido.
Ver Estadísticas:

Ultimas 24 horas: 8

Ultimos 7 días: 44

Ultimos 30 días: 182

Todo El Tiempo: 7,114