Sony PlayStation 3 Move es un controlador inalámbrico que funciona en el espacio 3D. El Move se combina con una PlayStation Eye Camera para que el juego cobre vida para el jugador. La reparación es sencilla y requiere destornilladores comunes y herramientas de palanca. Número de modelo del controlador de movimiento: CECH-ZCM1U. Número de modelo de cámara ocular: SLEH-0048.

Preguntas 19 Ver todo

My controller is chagred but behaves as if it has no charge.

I have two move controllers and both were low on battery life so I charged them both on my way to bed. The next morning one worked and the other did not. When connecting to a power source it blinks quickly then goes dark. It does the same when I use it to try and power up the PS3. Where the working one flickers and eventually syncs giving a solid red light at the bottom of the controller the malfunctioning one will not. It flickers then goes dead without ever having turning on the PS3.

Contesta esta pregunta Yo también tengo este problema

Es esta una buena pregunta?

Puntuación 3
Agregar un comentario

3 Respuestas

Respuesta Más Útil

Sounds daft, but have you tried hitting the reset button on the back? Similar to the six-axis controllers look for a little hole big enough for a paperclip and depress the switch for approx 10 secs. Then try and sync the device.

Fue útil esta respuesta?

Puntuación 3

1 comentario:

that's the 1st thing I tried. No change! Is it possible that the battery has burned out from leaving it on the charger? The unit works fine while its plgged onto the usb but dies as soon as it's taken off. Battery doesn't seem to take a charge at all. Is it possible to purchase a new battery and replace it myself?

This is a great site! thanks for your help.

CC Pullen

- de

Agregar un comentario

Great!!

I hit the reset button and my Move controller start working again. I thought that the battery was malfunctioning.

Fue útil esta respuesta?

Puntuación 0
Agregar un comentario

I had this problem with my son’s motion controllers. I took the batteries out and charged them separately using a bench power supply set to 4.2v and 1.3A maximum. Once the current had dropped below 700mA I reinstalled them and they now work normally. It appears that when the batteries are deeply discharged, the USB charging can’t cope and they need some more powerful charging. I hope that helps.

Fue útil esta respuesta?