Esta versión puede contener ediciones incorrectas. Cambie a la última instantánea verificada.
Qué necesitas
-
Este paso está sin traducir. Ayuda a traducirlo
-
Unplug the monitor for 24-48 hours. Wait 5-7 days before swapping the filter capacitor.
-
-
Este paso está sin traducir. Ayuda a traducirlo
-
Remove the 4 screws from the monitor stand with a Philips #1 screwdriver. Remove the bottom screws first.
-
-
Este paso está sin traducir. Ayuda a traducirlo
-
Sort this screw separately, as it is unique.
-
Remove 4 fine threaded screws from the back of the monitor with a Phillips #0 screwdriver. All of these screws are the same.
-
-
Este paso está sin traducir. Ayuda a traducirlo
-
On the bottom of the monitor, there are four slots to open the monitor. To release these clips, use a Jimmy or flathead screwdriver.
-
-
Este paso está sin traducir. Ayuda a traducirlo
-
With the monitor unclipped on the bottom, pull the sides of the monitor up. Do this slowly to avoid cracking the LCD.
-
-
Este paso está sin traducir. Ayuda a traducirlo
-
With the back of the monitor off, remove the 2 screws on the IEC power connector using a Phillips #0 screwdriver.
-
-
Este paso está sin traducir. Ayuda a traducirlo
-
Remove the 4 screw pins for the video cables from the monitor. Use a 5mm Nut bit/driver to remove the screw pins from the power supply shield.
-
-
-
Este paso está sin traducir. Ayuda a traducirlo
-
Disconnect the CCFL cables from the power supply board.
-
-
Este paso está sin traducir. Ayuda a traducirlo
-
Disconnect the flat flex cable that goes to the control board.
-
-
Este paso está sin traducir. Ayuda a traducirlo
-
Remove the 2 lower screws that hold the power supply shield to the monitor with a Phillips #0 screwdriver.
-
-
Este paso está sin traducir. Ayuda a traducirlo
-
On the right side of the monitor, remove the remaining screws holding the shield in place.
-
Lift the lower plate up while removing the power supply shield to remove it from the monitor. Once this is done, you will have access to the power supply.
-
-
Este paso está sin traducir. Ayuda a traducirlo
-
This capacitor is only found on older power supplies. Replacement is advised, but not required.
-
With the power supply shield removed from the monitor, identify the power supply. Take note of the values, including the inverter cap (if present).
-
Remove the 4 screws from the power supply. Once this is done, lift up the power supply at a slight angle to clear the chassis. Do not lift too much or the connector may be damaged!
-
-
Este paso está sin traducir. Ayuda a traducirlo
-
If you are unsure of the position of the capacitors, mark the polarity with a permanent marker. If the capacitors are incorrectly installed, they will explode when power is applied.
-
-
Este paso está sin traducir. Ayuda a traducirlo
-
To prepare the board for capacitor replacement, add flux or solder.
-
-
Este paso está sin traducir. Ayuda a traducirlo
-
Move to a workspace with ventilation or use a fume extractor. Once in an appropriate workspace, desolder the old capacitors. Heat up each leg and remove it.
-
After removing the capacitors, clean up the old solder with a desoldering braid. Lift it with the iron when removing it.
-
-
Este paso está sin traducir. Ayuda a traducirlo
-
Install the new capacitors. Check the polarity and bend the leads so they do not come loose during installation.
-
-
Este paso está sin traducir. Ayuda a traducirlo
-
Once the polarity is verified, solder the capacitors in. After installation, cut off any excess lead.
-
-
Este paso está sin traducir. Ayuda a traducirlo
-
After verifying there are no cold solder joints, clean the board. This can be cleaned with 91%+ Isopropyl or denatured alcohol.
-
Cancelar: No complete esta guía.
12 personas más completaron esta guía.
28 comentarios
I did not replace the large capacitor on the Acer monitor yet. All other caps have been replaced. I may have to replace the FSPO55- ZP102A as it has a hot spot beside it. I don't know if the part number is right? Do know where I can buy it. Tom B
These older CCFL panels usually burn on the PCB by the inverter coil and main transformer (the Delta branded part, in this case). The LED monitors limit the failure points to the transformer.
It sounds like your PCB got burned from the heat by the transformer or the inverter coil. This is very common and the boards are designed to take it. However, if you are concerned you should buy a new power supply board altogether if that makes you more comfortable.
Nick -
In step 12, replacing the capacitors with ones with a different capacitance rating instead of using a capacitor rated for higher voltage makes no sense to me electrically. The capacitance rating is the important part, if you use a capacator rated for say 35 volts when the original is rated for 10 makes no difference whatsoever. the rating just means MAX voltage.