Dometic Service Tips
SERVICE TIPS
AMES/AES/ROYALE/ELITE REFRIGERATORS
Models
| SILHOUETTE | DOMETIC | DOMETIC | DOMETIC |
| AMES/AES | AMES/AES | ROYALE | ELITE |
| S1521 | RM2607 | RM3662 | RM4872 |
| S1531 | RM2611 | RM3663 | RM4873 |
| S1621 | RM2807 | RM3862 | |
| S1631 | RM2811 | RM3863 | |
| S1821 | RM3607 | ||
| S1831 | RM3807 |
Refrigerator Start-Up Information
The new Dometic Refrigerator has been designed to provide more cooling power than ever before — surpassing all agency requirements and customer expectations. When starting this refrigerator for the very first time, the cooling cycle may require up to four hours of running time before the cooling unit is fully operational.
REVISION:
Form No. 3309479.008 10/04
(Replaces OS1662)
©2004 Dometic Corporation
LaGrange, IN 46761
THE MOST COMMON SYSTEM PROBLEMS ASSOCIATED WITH THE S1521, S1531, S1621, S1631, S1821, S1831, RM2607, RM2611, RM2807, RM2811, RM3607, RM3807, RM3662, RM3663, RM3862, RM3863, RM4872 and RM4873 REFRIGERATORS.
SYMPTOM
| 1. | No operation - no panel lights | Operation DC Volts Fuse Wiring Upper Circuit Board Lower Circuit Board |
| 2. | No operation - has panel lights | Operation DC Volts Thermistor Fuses Upper Circuit board Wiring Lower Circuit Board |
| 3. | No AC operation - operates on other mode(s) | Operation AC Volts Fuse Heating Element Upper Circuit Board Wiring Lower Circuit Board |
| 4. | No DC operation - operates on other mode(s) | Operation DC Volts Fuse Heating Element Upper Circuit Board Wiring Lower Circuit Board |
| 5. | No gas operation - operates on other mode(s) | Operation LP Gas Manual Gas Valve Igniter High Voltage Cable Electrode Solenoid Upper Circuit Board Wiring Lower Circuit Board |
| 6. | Insufficient cooling on all mode(s). | Ventilation Leveling Ambient Temperature Air Leaks Thermistor Cooling Unit Thermistor Adjuster |
SYMPTOM
-
Insufficient cooling on AC-cools properly on other mode(s)
-
Insufficient cooling on DC - cools properly on other mode(s)
-
Insufficient cooling on gas - cools properly on other mode(s)
-
Freezes
-
Changes preset mode
-
Check light on
CAUSE
AC Volts
Heating Element
Lower Circuit Board
- Interior light on when door is closed
DC Volts
Heating Element
Wiring
Lower Circuit Board
Thermistor
Thermistor Adjuster
Lower Circuit Board
Upper Circuit Board
LP gas
Orifice
Flue Baffle
Flue Tube
Flue Cap (if equipped)
Burner
Lower Circuit Board
Operation
DC Volts
Wiring
Upper Circuit Board
Lower Circuit Board
-
Rapid formation of frost
-
Water on frame
DC Volts
Wiring
LP Gas
Manual Gas Valve
Solenoid
Orifice
Burner
Lower Circuit Board
Thermocouple
Wiring
Door Switch
Door Position
Food Storage
Interior Liner to Frame
High Humidity
Air Leaks
Interior Liner to Frame
High Humidity
Air Leaks
Climate Control Heater
ICE MAKER SECTION
SYMPTOM
-
Ice Maker fails to start.
-
Ice Maker won't make ice.
-
Keeps making ice and won't shut off.
-
Not making enough ice.
-
Too much water is coming out.
-
Ejector blade frozen into ice cubes.
-
Unit is hooked-up no water comes in.
-
Ice maker is running but won't make cubes.
-
Ice maker will not make ice.
CAUSE
Operation
Arm in Up Position
AC Voltage
Water Valve
Ice Maker Cycle
Blades Frozen in Ice
AC Voltage
Water Valve
Ice Maker Cycle
Shut-off arm
Operation
Mold Thermostat
Cube Size
Ice Maker Cycle
Water Fill Adjustment
Water Valve
Water Fill Adjustment
Water Valve
Water
Water Valve
Water
Shut-Off Arm
Mold Thermostat
Hold Switch
Ice Ejector
Mold Heater
Timing Motor
AMES REFRIGERATOR OPERATION
2-WAY DISPLAY PANEL

ON 1 OFF AC 2 GAS CHECK COLD 1 2 3 4 5 COLDEST
3-WAY DISPLAY PANEL

ON DC AUTO CHECK COLD 1 2 3 4 5 COLDEST OFF AC GAS B C E F
MODELS INCLUDE: S1521, S1531, S1621, S1631, S1821, S1831, RM2607, RM2611, RM2807, RM2811
AUTO MODE
When operating in the AUTO mode, the AUTO mode indicator lamp (D) will illuminate. The control system will automatically select between AC and GAS operation with AC having priority over GAS. Either the AC indicator lamp (B) or the GAS indicator lamp (C) will illuminate depending on the energy source selected by the control system. If the control system is operating with AC energy and it then becomes unavailable, the system will automatically switch to GAS. As soon as AC becomes available again, the control will switch back to AC regardless of the status of GAS operation.
GAS MODE
When operating in the GAS mode, the AUTO mode indicator lamp (D) will not be illuminated. This mode provides LP gas operation only. The control system will activate the ignition system and will attempt to light the burner for a period of approximately 45 seconds. If unsuccessful, the CHECK indicator lamp (E) will illuminate and the GAS mode indicator lamp (C) will turn off.
To restart GAS operation, press the main power ON/OFF button (1) to the OFF and then ON position. The control system will attempt a new 45 second ignition sequence. If the refrigerator has not been used for a long time or the LP tanks have just been refilled, air may be trapped in the supply lines. To purge the air from the lines may require resetting the main power ON/OFF button (1) three or four times. If repeated attempts fail to start the LP gas operation, check to make sure that the LP gas supply tanks are not empty and all manual shutoff