Saltar al contenido principal

50" Plasma TV by Sanyo released in 2007.

Preguntas 80 Ver todo

fuse by logic board keeps blowing

what component should i be looking for if the fuse by the logic board keeps blowing? is that board the power supply where the power chord enters the unit?

Contestado! Ver respuesta Yo también tengo este problema

Es esta una buena pregunta?

Puntuación -1
Agregar un comentario

1 Respuesta

Solución Elegida

acloehlein, there are numerous things that could be causing that. Of course, first make sure that you have the right fuse. FT8ah250vp should be the one on the power board. If it continues to blow, you need to check the components on the logic board. Use a multimeter to check the Diode's, Caps and mosfets' on the board. Look for anything obvious, like charred components etc. Yes, that board is the powerboard and is available at places like this.

Fue útil esta respuesta?

Puntuación 2
Agregar un comentario

Añadir tu respuesta

acloehlein estará eternamente agradecido.
Ver Estadísticas:

Ultimas 24 horas: 0

Ultimos 7 días: 0

Ultimos 30 días: 0

Todo El Tiempo: 1,461