Saltar al contenido principal

Secadoras fabricadas por Maytag

Preguntas 88 Ver todo

Dryer not working after replacing parts

I have a Maytag performa electric dryer the heat was coming out just cold air. I replaced heating element, thermostat thermal fuse, and still no heat… not sure of what else to do. I am a woman here trying to fix this. Thank you.

Contesta esta pregunta Yo también tengo este problema

Es esta una buena pregunta?

Puntuación 0
1 comentario

Hi Kelly,

What's the model number of your dryer? That way we can get you the exact information you need to diagnose and fix your dryer.

- de

Agregar un comentario

1 Respuesta

Respuesta Más Útil

Check your fuse box. It's quite common for a dryer to have two circuit breakers, one for each 120V leg, making a total of 240V going to the dryer. If one of those breakers has tripped but not the other, then your dryer can be getting 120V, which is enough to power the electronics and the motor, but not enough to run the heat.

If you have a voltmeter, measure the power at the plug to verify you're getting somewhere between 220 and 240 volts to the dryer.

Once we know your model number we can give you more information on things like whether there are multiple thermal fuses that you might need to check, etc.

Fue útil esta respuesta?

Puntuación 1
Agregar un comentario

Añadir tu respuesta

Kelly M jones estará eternamente agradecido.
Ver Estadísticas:

Ultimas 24 horas: 2

Ultimos 7 días: 3

Ultimos 30 días: 11

Todo El Tiempo: 91