No hot water in boiler, keeps flashing F5?

My furriol boiler keeps flashing F5, and am only getting hot water for a couple of seconds at a time, will i need to get a new boiler, or can this be fixed?

¡Contestado! View the answer I have this problem too

Is this a good question?

Puntuación 1

Comentarios:

Have you switched boiler off and re-pressurised the system?

by

Yes turned it off and turn it back on left it for a period of time

by

Añadir un comentario

Kits de Reparación de Android

Estás a un kit de tu nueva pantalla o batería.

Comprar Ahora

Kits de Reparación de Android

Estás a un kit de tu nueva pantalla o batería.

Comprar Ahora

1 Respuesta

Solución elegida

Lindsey, not sure what boiler you have, the only info I got is for a Ferroli boiler. Again, there are numerous of those. If you can a model number would be helpful. On the Ferroli Optimax the F5 error code is:

Fan problem

• Tachometer signal

interrupted, fan connection

• Fan damaged, debris in fan

Possible Solution

• Check the wiring and fan

• Check the fan, clean debris

Hope this helps you to get started. Good Luck.

¿Ha sido útil esta respuesta?

Puntuación 3

Comentarios:

F5 fault What a nightmare! I removed the fan and checked the fan using a plugged twin cable attached to the live and neutral point of connection on the fan itself. After discovering it was seized I had to buy another, that was the easy part!!!

Installation was a success but the fan still wouldn’t work it seems to be a PCB problem.

My advice to homeowners and engineers You spot a ferroli run away!

by