Saltar al contenido principal

Secadora popular de ropa de Kenmore

Preguntas 60 Ver todo

Can a blown Cutoff fuse keep my dryer from starting

Changed thermal fuse and fixed heater coil that was grounded. It blew the timer which I also fixed and have Continuity everywhere except the cutoff fuse. It still won’t start. Is this why are is it Control panel issues?

Update (09/29/2020)

Roper mod# red4640YQ1

Contestado! Ver respuesta Yo también tengo este problema

Es esta una buena pregunta?

Puntuación 0
4 comentarios

It’s an older Roper model

- de

I’ll get a better description if you need when I get off this afternoon

- de

Thank you I really appreciate it!!

- de

Update: the fuse was changed and dryer is running.... but now it just starts before pressing the start switch!!! Any suggestions?

- de

Agregar un comentario

1 Respuesta

Solución Elegida

What exact model is this? We need to know that in order to try and look at the schematic and yes a bad cutoff can be the issue, but there may be more going on here.

Update (10/01/2020)

Ben Lewis, I can confirm that if the fuse is bad the dryer won't start or will run but not heat. So I would suggest to start with the fuse.

Fue útil esta respuesta?

Puntuación 1

1 comentario:

I posted in the old comments didn’t know if you would see it but the fuse worked but now when I put it on a cycle it just starts up before pressing start switch

- de

Agregar un comentario

Añadir tu respuesta

Ben Lewis estará eternamente agradecido.
Ver Estadísticas:

Ultimas 24 horas: 0

Ultimos 7 días: 1

Ultimos 30 días: 3

Todo El Tiempo: 100