Refrigerator not getting cold

Block Image

I had someone come out and check my refrigerator and they said was low on Freon so they filled it. However, refrigerator part still not cold but freezer is.

I noticed now I have water on floor and wasnt before and frost on copper line in back by compressor this normal? I had them come back out now saying it’s compressor fan but that is running. I did check evaporator fan as well and looks like its running. What else could be the issue? They want to charge me again and I think got scammed.

Contestado! Ver respuesta Yo también tengo este problema

Es esta una buena pregunta?

Puntuación 1
Agregar un comentario

1 Respuesta

Solución Elegida

If a refrigerator is low on refrigerant that means it has a leak. The sealed system is sealed and should not leak. When there is a leak, air and moisture enter the system. That is not good. It will cause the copper lines to erode and flake. This will cause a restriction in refrigerant flow. A restriction will cause the refrigerant lines to freeze up. When the refrigerant doesn’t flow properly your refrigerator won’t cool properly

You should not see frost on any copper lines. I would have the technician come back out and check the system. If it was me, i would recover the refrigerant, replace the filter dryer, repair all leaks, pull a vacuum to remove all moisture, then recharge the system.

Fue útil esta respuesta?

Puntuación 2
Agregar un comentario

Añadir tu respuesta