LG Refrigerator Water Inlet Valve Assembly Test and Replacement, Test the inlet valve assembly: paso 0, imagen 1 de 3 LG Refrigerator Water Inlet Valve Assembly Test and Replacement, Test the inlet valve assembly: paso 0, imagen 2 de 3 LG Refrigerator Water Inlet Valve Assembly Test and Replacement, Test the inlet valve assembly: paso 0, imagen 3 de 3
Test the inlet valve assembly
  • If you have a multimeter, you can use it to test the inlet valve assembly components.

  • Set the multimeter to the ohm (Ω) setting.

  • For the first solenoid, test the resistance between the wires from it at the connector.

  • The acceptable resistance is 360 to 420 Ω.

  • Repeat the test on the connector for the other solenoid.

  • The acceptable resistance is 360 to 420 Ω.

  • To test the flow meter, test the resistance between the wires from it at the connector.

  • The acceptable resistance is 4 kΩ to 30 kΩ.