'''Pressure Switch'''

The pressure switch closes when the proper airflow is achieved, signaling the control board to continue the ignition process. If the pressure switch is defective, the ignition process will stall, and the water heater will not light.

'''Thermocouple'''

The thermocouple detects the pilot flame. If the thermocouple does not detect a flame, the ignition process will stall, and the burner will not light