Saltar al contenido principal
Ayuda

Versión actual por: Tom Chai ,

Texto:

I don't have the schematics for 6P, however it should be largely similar to 6. C 1267 is a VCC bypass cap, so one end would be VCC_MAIN and the other would be GND. Just probe it to see which is which.
 
Electrically any GND would do, however regarding to board layout, bridging it to another GND may cause interference problems, which is exactly what bypass caps intend to reduce, so it can be pointless.
Electrically any GND would do, however regarding to board layout, bridging it to another GND may cause interference problems, which is exactly what bypass caps intend to reduce, so it can be pointless.
 
Just leave it empty and see if the result is acceptable.

Estatus:

open

Aporte original por: Tom Chai ,

Texto:

I don't have the schematics for 6P, however it should be largely similar to 6. C 1267 is a VCC bypass cap, so one end would be VCC_MAIN and the other would be GND. Just probe it to see which is which.

Electrically  any GND would do, however bridging it to another GND may cause interference problems, which is exactly what bypass caps intend to reduce, so it can be pointless.

Just leave it empty and see if the result is acceptable.

Estatus:

open