+ | [* icon_note] If you have a multimeter, you can use it to test the inlet valve assembly components. |
---|---|
+ | [* icon_note] Set the multimeter to the ohm (Ω) setting. |
+ | [* black] For the first solenoid, test the resistance between the red and blue wires on the white connector. |
+ | [* icon_note] The acceptable resistance is 360 to 420 Ω. |
+ | [* black] Repeat the test on the yellow connector for the other solenoid. |
+ | [* icon_note] The acceptable resistance is 360 to 420 Ω. |
+ | [* black] To test the flow meter, test the resistance between the red and black wires on the white connector. |
+ | [* icon_note] The acceptable resistance is 4 kΩ to 30 kΩ. |