+[title] Replace Burned Out Main Power Switch
+[* black] Apparently W-11 is obsolete and replaced by W-32 which is also obsolete.
+[* black] Main power switch was burned out. You can see lots of black around contacts of switch I took apart.
+[* black] I replaced it with a rocker switch (Digikey SW323-ND, $1 switch + $5 shipping). It's the wrong color but brown switches are hard to find.
+[* black] New switch has on/off marking. Original switch always annoyed me because I could not tell if it was on or off.