Before disassembly, make sure that the device is unplugged.
  • Before disassembly, make sure that the device is unplugged.

  • Unscrew the two 17.83 mm black screws located on the handle.

Agregar Comentario

Separate the shell from the main component.
  • Separate the shell from the main component.

  • Make sure that the each piece is free from debris.

Agregar Comentario

  • Continue to pull the components apart.

  • For reassembly, put the silver encasing on before the the black cover.

Agregar Comentario

  • Locate the thermal cutout under the coils of the heating element.

Agregar Comentario

  • Test the thermal cutout for continuity using the multimeter.

  • Make sure the multimeter is set to 200 ACV and bring the probes toward the thermal cutout.

  • If the numbers on the multimeter continue to change, the circuit is closed and properly functioning.

  • If the multimeter reads a consistent number, the circuit is opened and the thermal cutout needs to be replaced.

Agregar Comentario

  • To replace the thermal cutout, use the spudgers to extract the object.

  • To remove, wedge it back and forth until it comes free.

  • You do not need to take out the gold piece, only the thermal cutout.

Agregar Comentario

  • Replace the old thermal cutout with a new thermal cutout by snapping it into place.

Agregar Comentario

Conclusión

To reassemble your device, follow these instructions in reverse order.

Jessica Leyva

Miembro Desde 18/09/12

80 Reputación

5 Guías creadas

Equipo

Cal Poly, Team 1-5, Propen Fall 2012 Miembro de Cal Poly, Team 1-5, Propen Fall 2012

CPSU-PROPEN-F12S1G5

3 Miembros

5 Guías creadas

Agregar Comentario

Ver Estadísticas:

Ultimas 24 Horas: 0

Últimos 7 Días: 1

Últimos 30 Días: 4

Todo El Tiempo: 1,434