Introducción

This guide will instruct on how to replace a malfunctioning Viewfinder assembly on the RCA CC310.

Partes

No se requieren partes.

  1. Slide a spudger between the plastic rail and the metal tab on the left side of the rail.  Push away from the camcorder to release the flap. Pushing the viewfinder assembly to the right makes lifting the flap easier.
    • Slide a spudger between the plastic rail and the metal tab on the left side of the rail. Push away from the camcorder to release the flap.

    • Pushing the viewfinder assembly to the right makes lifting the flap easier.

    • Slide the lifted flap towards the viewfinder assembly until the viewfinder is free from the rail.

  2. Unscrew the 7mm ph#0 screw on the underside where the cable connects. Lift the plastic where the cable connects off of the viewfinder assembly. Disconnect the cable inside by pulling it apart.
    • Unscrew the 7mm ph#0 screw on the underside where the cable connects.

    • Lift the plastic where the cable connects off of the viewfinder assembly.

    • Disconnect the cable inside by pulling it apart.

  3. Unscrew two 7.0mm ph#0 screws on the underside of the viewfinder assembly. Lift the viewfinder plastic assembly up and remove.
    • Unscrew two 7.0mm ph#0 screws on the underside of the viewfinder assembly.

    • Lift the viewfinder plastic assembly up and remove.

  4. ¡Envío gratuito para todos los pedidos de más de USD100.00 o que contengan un Pro Tech Toolkit!

    Visita Nuestra Tienda

    ¿Alguna vez arreglaste algo? Eso es genial.

    Comparte tu historia de reparación con #SoyUnGenio

    Todos somos Genios

    Comparte tu historia de reparación con #SoyUnGenio

  5. Flip back the viewfinder access tab.
    • Flip back the viewfinder access tab.

    • Unscrew the 7.0mm ph #0 screw next to the mirror.

  6. Lift off both sides of the plastic assembly. When reassembling, if the housing doesn't connect properly, try turning the focus wheel. When reassembling, if the housing doesn't connect properly, try turning the focus wheel.
    • Lift off both sides of the plastic assembly.

    • When reassembling, if the housing doesn't connect properly, try turning the focus wheel.

  7. Lift the microphone circuit board straight up. Unclip the cable connected to the circuit board.
    • Lift the microphone circuit board straight up.

    • Unclip the cable connected to the circuit board.

  8. Lift plastic housing and guide the wires from underneath. Lift out the entire circuit board and viewfinder. Replace entire circuit board and viewfinder assembly.
    • Lift plastic housing and guide the wires from underneath.

    • Lift out the entire circuit board and viewfinder.

    • Replace entire circuit board and viewfinder assembly.

Conclusión

To reassemble your device, follow these instructions in reverse order.

Oliver Adams

Miembro Desde 19/01/11

620 Reputación

6 Guías creadas

Equipo

Cal Poly, Team 5-20, Amido Winter 2011 Miembro de Cal Poly, Team 5-20, Amido Winter 2011

CPSU-AMIDO-W11S5G20

4 Miembros

7 Guías creadas

Ver Estadísticas:

Ultimas 24 Horas: 0

Últimos 7 Días: 1

Últimos 30 Días: 9

Todo El Tiempo: 1,693