  1. ProScan PLT7223G Front Facing Camera Replacement, Front Facing Camera: paso 1, imagen 1 de 1
    • Remove both 4 mm screws on the top of the tablet with a PH00 screw driver.

  2. ProScan PLT7223G Front Facing Camera Replacement: paso 2, imagen 1 de 1
    • Use the blue plastic opening tool to pry open the tablet.

    • You will hear popping sounds. That's okay.

    • Be careful when using the blue plastic opening tool on the side of the device near the speakers, as there is a wire here that connects the speakers to the motherboard.

  3. ProScan PLT7223G Front Facing Camera Replacement: paso 3, imagen 1 de 1
    • With a spudger, flip up the ZIF connector that connects the camera's ribbon cable to the motherboard. This will release the ribbon cable.

  4. ProScan PLT7223G Front Facing Camera Replacement: paso 4, imagen 1 de 1
    • Remove the black tape holding down the ribbon cable.

  5. ProScan PLT7223G Front Facing Camera Replacement: paso 5, imagen 1 de 1
    • Remove camera.

Conclusión

To reassemble your device, follow these instructions in reverse order.