  1. Panasonic Lumix DMC-G5 Diopter Adjustment Dial Replacement, Diopter Adjustment Dial: paso 1, imagen 1 de 3 Panasonic Lumix DMC-G5 Diopter Adjustment Dial Replacement, Diopter Adjustment Dial: paso 1, imagen 2 de 3 Panasonic Lumix DMC-G5 Diopter Adjustment Dial Replacement, Diopter Adjustment Dial: paso 1, imagen 3 de 3
    • Remove the four 4.6mm J000 Phillips screws from the sides and two 3.2mm J000 Phillips screws along the bottom.

  2. Panasonic Lumix DMC-G5 Diopter Adjustment Dial Replacement: paso 2, imagen 1 de 3 Panasonic Lumix DMC-G5 Diopter Adjustment Dial Replacement: paso 2, imagen 2 de 3 Panasonic Lumix DMC-G5 Diopter Adjustment Dial Replacement: paso 2, imagen 3 de 3
    • Remove the two 3.2mm J000 Phillips screws located on the bottom edge of the viewfinder cover.

    • Carefully remove the viewfinder cover.

    • Remove the two 4.4mm J000 Phillips screws located near the top edge of the viewfinder.

  3. Panasonic Lumix DMC-G5 Diopter Adjustment Dial Replacement: paso 3, imagen 1 de 3 Panasonic Lumix DMC-G5 Diopter Adjustment Dial Replacement: paso 3, imagen 2 de 3 Panasonic Lumix DMC-G5 Diopter Adjustment Dial Replacement: paso 3, imagen 3 de 3
    • Slide the Wide Plastic Opening Tool upwards along the underside of the rear casing.

    • Be careful not to disconnect the filament connections. Reinserting them can be difficult.

    • Slowly lower the casing into the position shown.

  4. Panasonic Lumix DMC-G5 Diopter Adjustment Dial Replacement: paso 4, imagen 1 de 2 Panasonic Lumix DMC-G5 Diopter Adjustment Dial Replacement: paso 4, imagen 2 de 2
    • Use the Screwdriver J000 Phillips Head to remove the screw located at the lower-left corner of the face of the viewfinder glass.

    • Carefully lift the L-shaped clicker underneath the previously removed screw.

  5. Panasonic Lumix DMC-G5 Diopter Adjustment Dial Replacement: paso 5, imagen 1 de 2 Panasonic Lumix DMC-G5 Diopter Adjustment Dial Replacement: paso 5, imagen 2 de 2
    • Slide the faulty diopter adjustment dial off the rod.

    • Replace the diopter dial with a 1-cm wheel.

Conclusión

To reassemble your device, follow these instructions in reverse order.

Una persona más ha completado esta guía.

Equipo

USF Tampa, Team 1-3, Kass Spring 2017 Miembro de USF Tampa, Team 1-3, Kass Spring 2017

USFT-KASS-S17S1G3

4 Miembros

6 Guías creadas

0 comentarios

Agregar Comentario

Ver Estadísticas:

Ultimas 24 horas: 0

Ultimos 7 días: 0

Ultimos 30 días: 5

Todo El Tiempo: 1,008