Introducción

This guide shows you how to replace the spring on the power button.

  1. Turn the device upside down so that the three rubber pads are facing up.
    • Turn the device upside down so that the three rubber pads are facing up.

  2. Use a heat gun (set to low) to apply heat  to one of the rubber pads until you can easily remove the pad. This step takes around 5-7 minutes.
    • Use a heat gun (set to low) to apply heat to one of the rubber pads until you can easily remove the pad. This step takes around 5-7 minutes.

  3. Remove the heated rubber pad with a plastic opening tool.
    • Remove the heated rubber pad with a plastic opening tool.

    • Repeat steps 2 and 3 for the two remaining rubber pads.

  4. ¡Envío gratuito para todos los pedidos de más de USD100.00 o que contengan un Pro Tech Toolkit!

    Visita Nuestra Tienda
  5. Remove the six 1cm T-10 torx screws on the bottom of the device (found under the rubber pads) using a T-10 Torx screwdriver. Remove the six 1cm T-10 torx screws on the bottom of the device (found under the rubber pads) using a T-10 Torx screwdriver.
    • Remove the six 1cm T-10 torx screws on the bottom of the device (found under the rubber pads) using a T-10 Torx screwdriver.

  6. Open the device along its seam. Be careful when separating the device because there are wires connecting the two seperate halves. Be careful when separating the device because there are wires connecting the two seperate halves.
    • Open the device along its seam.

    • Be careful when separating the device because there are wires connecting the two seperate halves.

  7. Disconnect the ribbon cable connector from the top half of the device by pulling outward and parallel to the connecting pins.
    • Disconnect the ribbon cable connector from the top half of the device by pulling outward and parallel to the connecting pins.

  8. Locate and disconnect the two molex connectors found on either side of the ribbon cable connector on the bottom half of the device. Locate and disconnect the two molex connectors found on either side of the ribbon cable connector on the bottom half of the device.
    • Locate and disconnect the two molex connectors found on either side of the ribbon cable connector on the bottom half of the device.

  9. Pull the plastic button off the post. Pull the plastic button off the post.
    • Pull the plastic button off the post.

  10. Remove the metal U-clip (compressing the spring) with tweezers.
    • Remove the metal U-clip (compressing the spring) with tweezers.

Conclusión

To reassemble your device, follow these instructions in reverse order.

Equipo

Cal Poly, Team 9-28, Maness Winter 2014 Miembro de Cal Poly, Team 9-28, Maness Winter 2014

CPSU-MANESS-W14S9G28

4 Miembros

7 Guías creadas

Ver Estadísticas:

Ultimas 24 Horas: 0

Últimos 7 Días: 0

Últimos 30 Días: 4

Todo El Tiempo: 1,371