Unplug your fan.
-
Remove the 20 mm bolt that fastens the fan ring located at the bottom of the fan cage with a Phillips #3 screwdriver.
-
-
-
Remove the 8 mm bolt fastening the fan blades to the rotor with a Phillip #3 screwdriver.
-
-
-
Unscrew the four 8 mm bolts that fasten the back of the fan cage back to the motor housing with a Phillips #3 screwdriver.
-
-
-
-
Unscrew the 10 mm screw in the center hole of the oscillation knob with a Phillips #3 screwdriver.
-
-
-
Use your fingers to gently pull the power knob directly away from the motor housing.
-
-
-
Using a Phillips #3 screwdriver, unscrew and remove the 7 mm long bolt and small washer fastening the yellow and green wire to the motor housing support.
-
To reassemble your device, follow these instructions in reverse order.