Saltar al contenido principal

India Mark II Head Section Replacement

Guía Archivada
Esta guía se mantiene únicamente para fines históricos. Utiliza la última versión de la guía para llevar a cabo tu reparación.

Qué necesitas

  1. India Mark II Head Section Replacement, Cover Plate: paso 1, imagen 1 de 1
    • Use a wrench to remove the bolt on the top of the cover plate.

    • When replacing the cover plate, this bolt only needs to be hand tight.

  2. India Mark II Head Section Replacement: paso 2, imagen 1 de 1
    • Remove the top cover by pulling it straight off the pump.

    • Store the top cover in a sanitary place, preferably above ground, to prevent contamination.

  3. India Mark II Head Section Replacement, Head Section: paso 3, imagen 1 de 3 India Mark II Head Section Replacement, Head Section: paso 3, imagen 2 de 3 India Mark II Head Section Replacement, Head Section: paso 3, imagen 3 de 3
    • Pull the pump handle all the way down and hold it in this position, exposing the pump rod.

    • Place the spacer around the pump rod and under the chain attachment point.

    • Make sure the spacer is beveled side down, and flat side up.

    • Lift the pump lever until there is no tension in the chain and hold it in this position.

  4. India Mark II Head Section Replacement: paso 4, imagen 1 de 2 India Mark II Head Section Replacement: paso 4, imagen 2 de 2
    • Remove the bolt connecting the chain to the pump handle.

    • Remove the chain from the handle.

  5. India Mark II Head Section Replacement: paso 5, imagen 1 de 3 India Mark II Head Section Replacement: paso 5, imagen 2 de 3 India Mark II Head Section Replacement: paso 5, imagen 3 de 3
    • There are 4 bolts securing the head section to the water tank, located at the corners of head section base.

    • Continue supporting the pump handle so the pump head doesn't fall off when all the bolts are removed.

    • Remove the 4 bolts on the base of the water tank.

  6. India Mark II Head Section Replacement: paso 6, imagen 1 de 1
    • Lift the pump head off of the water tank and place in a sanitary place, preferably above ground, to prevent contamination.

Conclusión

To reassemble your device, follow these instructions in reverse order.