Follow these instructions to remove and replace a potentiometer on your guitar.

Gently place the instrument upside-down on a soft surface.
  • Gently place the instrument upside-down on a soft surface.

  • Locate the battery cavity cap and screws.

Agregar Comentario

Use a phillips head screwdriver to unscrew both screws. Two #1 1mm long screws.
  • Use a phillips head screwdriver to unscrew both screws. Two #1 1mm long screws.

Agregar Comentario

  • Remove the cap by lifting upwards to reveal the battery.

Agregar Comentario

  • Gently lift the battery from the cavity.

  • Detach the battery completely by firmly pulling the fabric connector from the conducting end of the battery.

Agregar Comentario

  • Locate back plate cap and screws.

Agregar Comentario

  • Use a phillips head screwdriver to remove the four screws,#1-1mm, by turning the screws counter-clockwise.

Agregar Comentario

  • Remove cap by lifting upwards, revealing the circuitry of the instrument.

Agregar Comentario

  • Turn the instrument over.

  • Locate the potentiometer knob.

  • Locate the allen screw socket on the knob.

Agregar Comentario

  • Use a 1/16" allen wrench to loosen the allen screw.

  • After the screw is loosened, lift the knob off of the instrument.

Agregar Comentario

  • Locate the potentiometer nut, at the base of the potentiometer piston.

  • Use the adjustable wrench to remove the nut from the potentiometer.

Agregar Comentario

  • Carefully turn the instrument over.

  • Remove the potentiometer from the instrument by gently pulling it upward.

Agregar Comentario

  • Use the soldering iron to release the black, yellow, and white wires from the side of the potentiometer.

  • The soldering iron is extremely hot. Avoid contact with skin, fabric or the body of the instrument. When soldering iron is not in use, rest it on the soldering iron stand.

Agregar Comentario

  • Use the soldering iron to release the black and green wires from the bottom of the potentiometer.

  • The soldering iron is extremely hot. Avoid contact with skin, fabric or the body of the instrument. When soldering iron is not in use, rest it on the soldering iron stand.

Agregar Comentario

Conclusión

To reassemble your device, follow these instructions in reverse order with a new potentiometer.

Chris Pittner

Miembro Desde 11/01/13

163 Reputación

7 Guías creadas

Equipo

Cal Poly, Team 5-18, Forte Winter 2013 Miembro de Cal Poly, Team 5-18, Forte Winter 2013

CPSU-FORTE-W13S5G18

4 Miembros

8 Guías creadas

Agregar Comentario

Ver Estadísticas:

Ultimas 24 Horas: 2

Últimos 7 Días: 4

Últimos 30 Días: 40

Todo El Tiempo: 2,116