Introducción

We will gain access to the screen, enabling us to replace it with a new screen.

  1. Place Visor Edge face down. Notice the tab connecting the flip cover to the back of the PDA.
    • Place Visor Edge face down.

    • Notice the tab connecting the flip cover to the back of the PDA.

    • Gently push tab forward.

    • Do not pull on the flip cover to try and remove it from the PDA.

  2. Remove the six 4.1 mm Phillips screws from the back plate using the #00 Phillips Scewdriver.
    • Remove the six 4.1 mm Phillips screws from the back plate using the #00 Phillips Scewdriver.

  3. Remove the black plate from the PDA.
    • Remove the black plate from the PDA.

  4. ¡Envío gratuito para todos los pedidos de más de USD100.00 o que contengan un Pro Tech Toolkit!

    Visita Nuestra Tienda

    ¿Alguna vez arreglaste algo? Eso es genial.

    Comparte tu historia de reparación con #SoyUnGenio

    Todos somos Genios

    Comparte tu historia de reparación con #SoyUnGenio

  5. Remove four 2.6 mm Philips screws that are on the sides of the frame. Remove the remaining 3.9 mm Philips screw holding together the stylus holster and the frame.
    • Remove four 2.6 mm Philips screws that are on the sides of the frame.

    • Remove the remaining 3.9 mm Philips screw holding together the stylus holster and the frame.

  6. Remove the four 2.6 mm Philips screws on the top and bottom of the frame. Remove the four 2.6 mm Philips screws on the top and bottom of the frame.
    • Remove the four 2.6 mm Philips screws on the top and bottom of the frame.

  7. Remove the white frame from the PDA.
    • Remove the white frame from the PDA.

    • The frame may get stuck on the corners so be very gentle when working the corners off.

  8. Pull front cover off gently.
    • Pull front cover off gently.

  9. With the device flipped over, use the tweezers to remove the ribbon cable attaching the screen to the circuit board. With the device flipped over, use the tweezers to remove the ribbon cable attaching the screen to the circuit board.
    • With the device flipped over, use the tweezers to remove the ribbon cable attaching the screen to the circuit board.

  10. Wedge the spudger in between the glass and the metal frame. Slide the spudger down the length of the screen to detach from the frame.
    • Wedge the spudger in between the glass and the metal frame.

    • Slide the spudger down the length of the screen to detach from the frame.

    • With your hands, pry the screen up from the detached side, and the screen will pop off.

Conclusión