If you need to repair anything on the DBPOWER T20 Projector you need to disassemble it first. This guide will show you all the steps necessary to disassemble the device to a point where items can be replaced. It is quite a sturdy device so don't be afraid to use some force removing the top of the device and the wired. However, use caution around the mirrors inside the device.

Partes

No se especificaron partes.

  1. Flip the device and lay flat.
    • Flip the device and lay flat.

  2. Remove the four (9 mm) screws with a PH2 screwdriver.
    • Remove the four (9 mm) screws with a PH2 screwdriver.

    • Remove the two (7 mm) located with a PH2 screwdriver.

  3. Flip the device over and pry the top off with a plastic opening tool. Flip the device over and pry the top off with a plastic opening tool. Flip the device over and pry the top off with a plastic opening tool.
    • Flip the device over and pry the top off with a plastic opening tool.

  4. Remove the ribbon cable connecting the motherboard to the button control board by gently pulling it from its connector.
    • Remove the ribbon cable connecting the motherboard to the button control board by gently pulling it from its connector.

  5. Remove four (6 mm) screws connecting the motherboard using a J0 screwdriver. Remove four (6 mm) screws connecting the motherboard using a J0 screwdriver.
    • Remove four (6 mm) screws connecting the motherboard using a J0 screwdriver.

  6. Remove the two cables connected to the motherboard: black power cable and the red/black fan cable. the black cable requires more force to remove than the other cables. the black cable requires more force to remove than the other cables.
    • Remove the two cables connected to the motherboard: black power cable and the red/black fan cable.

    • the black cable requires more force to remove than the other cables.

  7. Lift the black latch on the ZIF connector and remove the ribbon cable that attaches the digitizer to the motherboard. Lift the black latch on the ZIF connector and remove the ribbon cable that attaches the digitizer to the motherboard.
    • Lift the black latch on the ZIF connector and remove the ribbon cable that attaches the digitizer to the motherboard.

  8. Raise motherboard by lifting sideways and then up to avoid the ports.
    • Raise motherboard by lifting sideways and then up to avoid the ports.

  9. Remove wires attaching the piezoelectric speakers to the motherboard. Remove wires attaching the piezoelectric speakers to the motherboard.
    • Remove wires attaching the piezoelectric speakers to the motherboard.

  10. Remove the five screws securing the black plastic cover with a J0 screwdriver. Lift up and out to remove.
    • Remove the five screws securing the black plastic cover with a J0 screwdriver.

    • Lift up and out to remove.

Conclusión

To reassemble your device, follow these instructions in reverse order.

Una persona más ha completado esta guía.

Andrea Espinosa

Miembro Desde 15/02/18

433 Reputación

3 Guías creadas

Equipo

USF Tampa, Team S16-G2, Boczar Spring 2018 Miembro de USF Tampa, Team S16-G2, Boczar Spring 2018

USFT-BOCZAR-S18S16G2

5 Miembros

5 Guías creadas

Anyone find a bulb for this thing? And/or know what else (or a quick fix) would fix a dark or burn mark on the image?

jcr4130 - Contestar

haing the same issue tried to call a electronics repair place to see if the could order a new polarizing lens for me and they said they could not unless they were the ones that did the repair

derek_russell82308 -