    Remove the protective cover. This will easily unsnap from the main body.
    • Remove the protective cover. This will easily unsnap from the main body.

  2. Este paso está sin traducir. Ayuda a traducirlo

    Slide the tab located at the top of the calculator to the unlocked position.
    • Slide the tab located at the top of the calculator to the unlocked position.

  3. Este paso está sin traducir. Ayuda a traducirlo

    Slide the back cover down, and then pull the back plate away from the calculator.
    • Slide the back cover down, and then pull the back plate away from the calculator.

  4. Este paso está sin traducir. Ayuda a traducirlo

    Unscrew the back-up battery cover. (1 screw)
    • Unscrew the back-up battery cover. (1 screw)

  5. Este paso está sin traducir. Ayuda a traducirlo

    Remove all visible screws.
    • Remove all visible screws.

    • Note that there are more screws than shown in this picture (16 in total). You MUST remove them ALL.

  6. Este paso está sin traducir. Ayuda a traducirlo

    Keeping the front faceplate FACE DOWN on the work surface, lift the circuit board AND the plastic backing up and away from the faceplate.
    • Keeping the front faceplate FACE DOWN on the work surface, lift the circuit board AND the plastic backing up and away from the faceplate.

  7. Este paso está sin traducir. Ayuda a traducirlo

    These two components are loosely attached by the rectangular module just below the back-up battery.
    • These two components are loosely attached by the rectangular module just below the back-up battery.

  8. Este paso está sin traducir. Ayuda a traducirlo

    The warning label next to this module reads "Do not remove the rectangular module located under the test access panel as it is required for proper product operation!"
    • The warning label next to this module reads "Do not remove the rectangular module located under the test access panel as it is required for proper product operation!"

  9. Este paso está sin traducir. Ayuda a traducirlo

    The rubber mat in back of the faceplate may be removed, exposing all 77 individual plastic keys.
    • The rubber mat in back of the faceplate may be removed, exposing all 77 individual plastic keys.

    • CAUTION: These keys are loosely held in by gravity and will fall out if the faceplate is tilted to any extreme.

  10. Este paso está sin traducir. Ayuda a traducirlo

    The device has now been separated into as many component parts as intended by the manufacturer.
    • The device has now been separated into as many component parts as intended by the manufacturer.