The Kenmore Elite HE3 is 7.2 cu. ft. capacity electric dryer by Kenmore.

Preguntas 209 Ver todo

Dryer is not heating

The dryer will not heat on any setting.

Contestado! View the answer Yo también tengo este problema

Es esta una buena pregunta?

Calificación 2

Comentarios:

Have had a technician in to trouble shoot, he said he tested everything that could be tested. replaced the gas coil, still no heat.

por

Agregar un comentario

4 Respuestas

Solución Elegida

Thermal Fuse

The thermal fuse is a safety device designed to protect the dryer from overheating. The fuse is located on the blower housing or at the dryer’s heat source such as the heating element on electric dryers or at the burner on gas models. The fuse should be closed for continuity meaning it has a continuous electrical path through it when good. If overheated the fuse will have no continuity meaning the electrical path is broken and the fuse has blown out. A multimeter can be used to test it for continuity. Be aware that a blown thermal fuse is an indication of a restricted exhaust vent from the dryer to the outside. Always check the dryer venting when replacing a blown thermal fuse.

Fue útil esta respuesta?

Calificación 3

Comentarios:

Dryer rotated , element shows good, I replaced thermostat fuse...still not heating, what did I miss?

por

Ducts have been cleaned too

por

Betty what is the make and model number of your machine?

por

I'm having the same problem of no heat. Replaced thermal fuse and heating element, still no heat.

por

Model # 110.82822102

Kenmore elite HE3

por

Agregar un comentario
Esta respuesta fue originalmente para otra pregunta .

Where did you find this tech? The gas coil part costs around $8.00

Cause 1

Thermal Fuse

The thermal fuse is a safety device designed to protect the dryer from overheating. The fuse is located on the blower housing or at the dryer’s heat source such as the heating element on electric dryers or at the burner on gas models. The fuse should be closed for continuity meaning it has a continuous electrical path through it when good. If overheated the fuse will have no continuity meaning the electrical path is broken and the fuse has blown out. A multimeter can be used to test it for continuity. Be aware that a blown thermal fuse is an indication of a restricted exhaust vent from the dryer to the outside. Always check the dryer venting when replacing a blown thermal fuse.

Parts

Cause 2

Gas Valve Solenoid

Gas dryers have two or more gas valve solenoid coils. The gas valve solenoids open the gas valve ports to allow gas to flow into the burner assembly. If a gas valve solenoid fails, the dryer won’t heat. To determine if one or more of the gas valve solenoids has failed, check the igniter. If the igniter glows and goes out but does not ignite the gas, the gas valve solenoid is defective. If one or more of the gas valve coils are defective, we recommend that you replace them as a set.

Parts

Cause 3

Igniter

The igniter uses heat to ignite the gas in the burner assembly. If the igniter is not working, the gas will not ignite, preventing the dryer from heating. To determine if the igniter has burned out, use a multimeter to test the igniter for continuity. If the igniter does not have continuity, replace it.

Fue útil esta respuesta?

Calificación 1
Agregar un comentario
Esta respuesta fue originalmente para otra pregunta .

thermostat if it has one or the heating element

Fue útil esta respuesta?

Calificación 0
Agregar un comentario

My Dyer is not heating. Good Air Flow. I took the thermal fuse out and it reads '0' on my ohm meter which means both connectors are connected just fine. Sears Kenmore Elite HE3 Electric Dyer. Needless to say this was very disappointing.

Any ideas?

Fue útil esta respuesta?

Calificación 0
Agregar un comentario

Añadir tu respuesta

Angus estará eternamente agradecido.
Ver Estadísticas:

Ultimas 24 Horas: 62

Últimos 7 Días: 331

Últimos 30 Días: 1,205

Todo El Tiempo: 12,851